Hi Kevin,
That's a nice bunch of captures. You are a quick study! Here is one we thought would make for a good discussion. I'm off to the Vision Conference tomorrow but will post zooms on any areas, as requested, when I get a chance

Note the trigger settings. He has used the external trigger on #1 to devote the full sample rate to one channel while still syncing the capture for cylinder ID.
He has his samples turned up to 32.000 so at 5ms/div, he is sampling at 375,000 samples per second. This means that there is a sample every 2.7 millionths of a second. This is fast enough to display every max kv event and all the detail needed.
For comparison, a Fluke 97/98, at this time base, would be sampling at 6104 samples per second (true sample rate) Pico is over 61 times faster!
Ok, enough math. My head hurts.

I'll let you take it from here, Kevin. The game is, what's wrong with the car?