The Autonerdz Community Forums | |
https://www.autonerdz.com/cgi/yabb2/YaBB.pl
General Public Area >> PicoScope >> Sample rates https://www.autonerdz.com/cgi/yabb2/YaBB.pl?num=1102873537 Message started by NickUK on Dec 12th, 2004 at 9:45am |
Title: Sample rates Post by NickUK on Dec 12th, 2004 at 9:45am
Hi Tom (All) ,
Do all Labscopes follow the same rule that the true sample rate is always slightly more than the requested one? The Pico is listed as bieng 3000KHz - under what conditions would i ever see the result of that speed? Thanks Tom (All). Nick |
Title: Re: Sample rates Post by Tom Roberts on Dec 12th, 2004 at 10:49am
Hi Nick,
Usually, the true sample rate is less than the requested rate. As you reduce the time base to the point that the ADC can run at full speed without over filling the buffer, the ADC runs at full speed. You can't request more than the ADC can do ;) The reason that the actual rate reduces, at longer times, is that the ADC speed has to be stepped down when we have longer time bases. Otherwise, we would over fill the buffer. That's what the sample rate calculator is for. If you play with different times, buffer and speeds, you can see the effect. Here it is: http://www.autonerdz.com/java/SampleRateCalculator.html This can be used to compare the performance of different DSOs. |
The Autonerdz Community Forums » Powered by YaBB 2.5 AE! YaBB Forum Software © 2000-2010. All Rights Reserved. |